Pelvis-Inlet/Outlet View

DPL1-2LATH

ROUTINE: Inlet and Outlet views of pelvis.

DISTANCE: 44”

BUCKY: Yes

FOCAL SPOT: Large

IMAGING PLATE: 14x17 CR cassette

CENTRAL RAY:

  1. Inlet-35° caudal angle entering at midline at the level of the ASIS.
  2. Outlet-35° cephalic angle entering at midline at the symphysis.

Pelvis-Inlet/Outlet View

Updated 9/29/1999